6SL3300-7TG41-3AC0 is a Line Filter Module under Siemens' SINAMICS S120 series. It is a key EMC (Electromagnetic Compatibility) component in servo drive systems, primarily used to suppress electromagnetic interference (EMI) generated by the drive system, ensuring compliance with industrial EMC standards and stable operation of surrounding electrical equipment. Below is its detailed information:
Quantity
ADD TO CART
BUY IT NOW
  • Detail

    1. Basic Model & Classification

    Item Details
    Product Series SINAMICS S120 (Siemens' high-end integrated servo drive system, widely used in high-precision motion control fields)
    Module Type Line Filter (Input-side electromagnetic compatibility filter, for three-phase AC input)
    Full Model Number 6SL3 300-7TG41-3AC0 (Spaces follow Siemens' standard model formatting and do not affect identification)

    2. Core Technical Parameters

    Parameter Category Specific Specifications
    Rated Input Voltage 3AC 380-480V, 50/60Hz (Matches the input voltage of SINAMICS S120 series power modules)
    Rated Input Current 34A (Continuous operating current capacity, matching high-power S120 power modules)
    EMC Compliance Standard Complies with EN 61800-3 Category C2 (for industrial environments) and EN 55011 Class A
    Impedance Matching Optimized for SINAMICS S120 non-regenerative power modules (e.g., 6SL3330-7TG41-3AA3)
    Cooling Method Natural cooling (Passive heat dissipation, no additional fan required)
    Mounting Method Booksize (Compact design, compatible with S120 series cabinet mounting dimensions)
    Protection Class IP20 (For use inside enclosed control cabinets only; prevents finger contact with live components)
    Weight Approximately 3.2kg

    3. Main Functions & Applications

    Core Functions

    • Suppress Conducted Emissions: Filters high-frequency interference signals generated by the rectifier circuit of the servo drive's power module, preventing these signals from propagating to the public power grid and interfering with other electrical equipment (e.g., sensors, PLCs, communication devices).
    • Reduce Radiated Interference: Reduces electromagnetic radiation from the drive system's input power line, helping the entire equipment meet industrial EMC emission standards and avoid certification failures.
    • Improve Immunity: Enhances the drive system's resistance to external interference from the power grid (e.g., voltage spikes, surges), reducing system malfunctions caused by grid fluctuations.
    • System Compatibility: Designed specifically for SINAMICS S120 power modules, ensuring seamless integration without affecting the drive's dynamic performance.

    Applicable Scenarios

    • High-Precision Manufacturing Equipment: Such as CNC machining centers, precision grinding machines, and semiconductor manufacturing equipment—where electromagnetic interference can affect machining accuracy or sensor feedback.
    • EMC-Sensitive Environments: Factories with dense electronic equipment (e.g., electronics assembly lines, pharmaceutical production lines) or environments requiring strict EMC compliance (e.g., aerospace component manufacturing).
    • Public Grid Connection: Systems connected to the municipal power grid that need to comply with local EMC regulations to avoid penalties or disruptions to adjacent facilities.
    • Matching High-Power Drives: Specifically paired with 25kW-class SINAMICS S120 power modules to address interference issues of high-power drive systems.

    4. Key Matching & Precautions

    Matching Components

    • Mandatory Matching: Exclusively designed for SINAMICS S120 non-regenerative power modules with 34A rated input current (e.g., 6SL3330-7TG41-3AA3). Not compatible with regenerative power modules or modules of other power ratings.
    • Auxiliary Components: Should be installed close to the power module (distance ≤ 50cm) to ensure filtering effectiveness. No additional components (e.g., contactors) are allowed between the filter and the power module.
    • Power Supply Requirements: Must be used with a three-phase AC power supply that meets 380-480V specifications; overvoltage may cause permanent damage to the filter.

    Installation & Usage Precautions

    • Electrical Safety: Installed by qualified electrical engineers in accordance with Siemens' EMC installation guidelines. Ensure reliable grounding (the filter's PE terminal must be connected to the cabinet's protective ground with a cross-sectional area ≥ 16mm²).
    • Mounting Distance: Install directly adjacent to the matched power module to minimize the length of unfiltered power lines, which otherwise reduces filtering efficiency.
    • Wiring Specifications: Use shielded cables for input and output wiring, and ensure the shield is grounded at both ends to enhance interference suppression.
    • Maintenance Notes: The filter has no replaceable parts; if it fails (e.g., internal fuse blown, abnormal heating), it must be replaced entirely (do not disassemble for repair).
    • Environmental Requirements: Avoid installation in environments with high temperature (>40°C), high humidity (>90% RH, non-condensing), dust, or corrosive gases—these can accelerate component aging.

    Spare Parts & After-Sales

    • Classified as a standard EMC component for Siemens SINAMICS S120. Purchase through official authorized distributors to ensure compatibility and compliance with EMC standards.
    • For EMC testing or installation guidance, refer to the SINAMICS S120 EMC Guidelines or contact Siemens industrial technical support.

    Channels for Obtaining Detailed Information

    You can access more professional technical data through Siemens' official platforms:
  • Customer Reviews
    No comments