Home / 6SL3352-1AG31-2AA1

6SL3352-1AG31-2AA1

Contact for Price
WISHLIST
6SL3352-1AG31-2AA1
SPU: 6SL3352-1AG31-2AA1
6SL3352-1AG31-2AA1 is a Braking Module belonging to Siemens' SINAMICS S120 series. It is a key auxiliary component in the drive system, primarily responsible for consuming the regenerative energy generated by the motor during deceleration or load reduction, thereby stabilizing the DC link voltage. Below is its detailed information:
Quantity
ADD TO CART
BUY IT NOW
  • Detail

    1. Basic Model & Classification

    Item Details
    Product Series SINAMICS S120 (Siemens' high-end integrated servo drive system, widely applied in high-precision motion control scenarios)
    Module Type Braking Module (Regenerative energy dissipation module, also known as a "chopper module")
    Full Model Number 6SL3 352-1AG31-2AA1 (Spaces conform to Siemens' standard model formatting and do not impact identification)

    2. Core Technical Parameters

    Parameter Category Specific Specifications
    Rated DC Link Voltage 540V DC (Matches the DC bus voltage of SINAMICS S120 series power modules and motor modules)
    Rated Braking Current 20A (Continuous current capacity for energy dissipation)
    Peak Braking Current 60A (Short-term peak current, with duration compliant to Siemens drive specifications)
    Maximum Braking Power Approximately 10.8kW (Calculated based on rated DC link voltage and rated braking current)
    Cooling Method Forced air cooling (Requires effective ventilation in the control cabinet and reserved heat dissipation space)
    Mounting Method Booksize (Compact structural design, suitable for dense cabinet installation)
    Protection Class IP20 (Intended for use inside enclosed control cabinets only; protects against finger contact with live parts but is not dustproof or waterproof)
    Control Interface Integrated with SINAMICS S120 system (Automatically controlled by the system's control unit when DC link voltage exceeds the threshold)

    3. Main Functions & Applications

    Core Functions

    • Regenerative Energy Consumption: When the motor operates in the generating state (e.g., rapid deceleration, lowering heavy loads), it feeds regenerative energy back to the DC link, causing voltage rise. The braking module activates at this point, connecting the braking resistor to consume excess energy as heat, preventing overvoltage faults in the drive system.
    • Overvoltage Protection: Serves as a key safeguard for the DC link. It monitors the bus voltage in real-time and triggers braking action immediately once the voltage reaches the preset threshold (typically around 660V DC for 540V DC systems), ensuring stable operation of power modules and motor modules.
    • System Coordination: Seamlessly communicates with the SINAMICS S120 control unit (e.g., CU320-2) and power modules, realizing automatic activation/deactivation without additional independent control circuits.

    Applicable Scenarios

    • High-Dynamic Motion Systems: Such as CNC machine tools (where feed axes frequently accelerate/decelerate), robotic arms (with frequent start-stop and reversing movements), and high-speed conveying lines.
    • Potential Energy Load Applications: Including hoists, elevators, and stacking machines, where regenerative energy is generated when loads are lowered.
    • Large-Inertia Load Drives: For example, centrifuges and fans, which produce substantial regenerative energy during rapid deceleration.

    4. Key Matching & Precautions

    Matching Components

    • Mandatory Matching: Must be used with a braking resistor (Siemens recommended model: e.g., 6SL3000-0BE25-5AA0, with resistance and power matching the module's parameters). Using mismatched resistors may cause module damage or fire hazards.
    • Compatible Systems: Only applicable to SINAMICS S120 drive systems with a 540V DC link, matching power modules (e.g., 6SL3330 series) and motor modules (e.g., 6SL3320 series).
    • Control Unit Requirement: Relies on the SINAMICS S120 control unit (e.g., CU320-2 PN) for voltage monitoring and control logic execution.

    Installation & Usage Precautions

    • Electrical Safety: Installed by qualified electrical engineers in accordance with Siemens' guidelines. Ensure reliable grounding, and disconnect the main power supply before wiring or maintenance.
    • Heat Dissipation: Reserve a minimum of 50mm clearance around the module for air circulation. The braking resistor generates significant heat and should be installed in a well-ventilated area or separately in a resistor cabinet.
    • Resistor Matching: Strictly follow the module's technical manual to select braking resistors with appropriate resistance (minimum resistance not lower than the module's required value) and power rating to avoid overload burnout.
    • Environmental Requirements: Avoid installation in environments with high temperature (>40°C), high humidity (>90% RH, non-condensing), dust, oil fumes, or corrosive gases.

    Spare Parts & After-Sales

    • Classified as a standard industrial spare part for Siemens SINAMICS S120. Purchase through official authorized distributors to ensure authenticity and compatibility.
    • For technical issues (e.g., parameter setting, fault diagnosis), refer to the Siemens official manual or contact Siemens industrial technical support.
  • Customer Reviews
    No comments